Introduction to ISO Preparation of drawings for optical elements and systems and a few words about other optical standards. Table 1: Structure of ISO standard. Part 1 covers the mechanical aspects of optical drawings that are specific to optics and not already covered in one of. ISO ‐2 Stress Birefringence. The cooling process can create stress within glass. This leads to polarization effects. ISO‐2 Stress.

Author: Kejar Mezirn
Country: Haiti
Language: English (Spanish)
Genre: Finance
Published (Last): 6 August 2010
Pages: 40
PDF File Size: 2.11 Mb
ePub File Size: 15.23 Mb
ISBN: 287-5-88273-715-1
Downloads: 15990
Price: Free* [*Free Regsitration Required]
Uploader: Kagis

More information is provided in OP1. International Surface Imperfection Standard Presenter Dave Aikens is leading the project to overhaul and streamline the 10110-1 generation of the ISO international surface imperfection standard.

This is presumably done with a separate document, or a note. Chamfers are length of legs. You may experience issues viewing this site in Internet Explorer 9, 10 or In the drawing in slide 14 et seq. I’d like 1010-1 know if this standard applies to plastics as well.

Preparation of drawings for optical elements and systems. In this webinar he will 1010-1 the role of Tolerances measurementOptics, Technical drawing, Dimensions, Iao representation, Engineering drawings, Optical instruments, Drawings. Yes, any special optical material properties such as the crystallographic axis should be indicated on the drawing, but the standard does not offer any guidance 1010-1 how this is done, or what happens when it is 1010-1 indicated or toleranced.

Click to learn more. For non-standard durability requirements, the requirement is indicated in a note. Waveplates are drawn as windows with a note indicating their retardance in the drawing field. What is the length on bevel? How does ISO deal with defining crystal material requirements? Preparation of drawings for optical elements and systems Material imperfections.

  ANTONIO LAZCANO ARAUJO EL ORIGEN DE LA VIDA PDF

You may find similar items within these categories by selecting from the choices below:. Prisms can be drawn using ISO by indicating surface numbers in the drawing field and then adding additional columns to the table field. Take the smart route to manage medical device compliance.

T and R are used to specify Transmission and Reflectivity but how are the different polarizations handled, subscript? The best approach is to make a note on the drawing indicating that the slope is calculated on data which has been filtered with a smoothing function, such as a Chetwynd filter function. Subscribe FREE to our newsletters. Do all surface form tolerances 10110- after coating?

There is no guidance on crystal material properties or tolerances, so they must be provided in a note.

Find Similar Items This product falls into the following categories. Search all products by. Please download Chrome or Firefox or view our browser tips. ISO is a metrology standard, to validate a specific damage requirement via testing.

Slope calculations in ISO for texture use this as the default. Thus if the surface form is intended to apply prior to coating, there needs to be a note indicating this, or the coating needs to be on its own drawing. Your basket 10110–1 empty. Where do you cover the coating durability, on the drawing or a separate document? There is no default.

New Optics Drawings Standards

Note that the next edition of ISOwhich is expected in isi, will include new drawing formats that assist with these types of components. Generalites Title in German Optik und Photonik. We use cookies to improve user experience and analyze our website traffic as stated in our Privacy Policy. We use cookies to make our website easier to use and to better understand your needs.

  LOS BIENES TERRENALES DEL HOMBRE LEO HUBERMAN PDF

All indications apply to the finished part. By using this website, you agree to the use of cookies unless you have disabled them.

New Optics Drawings Standards | Webinars |

If substitutions are allowed, I recommend using the international glass code instead of the manufacturer product label. Accept and continue Learn more about the cookies we use and how to change your settings.

What is the surface texture on the annulus? A bevel must be specified and toleranced uso, including indication of angle, length, etc. Tim Dykstra, product sales manager for Concept Systems Inc.

A subscript of p and s is used for linear polarizations. What is the best way to indicate allowed glass substitutions or if substitutions are not allowed?

ISO is the notation standard to allow you to put a laser damage requirement on the drawing.

18/30345242 DC

How about prisms, waveplates, etc. Preparation of drawings for optical elements and systems Table representing data of optical elements and cemented assemblies BS ISO There is a lot of specific mention to glass. This website is best viewed with browser version of up to Microsoft Internet Explorer 8 or Firefox 3.

The Zygo way of pixel to pixel gradients IS resolution sensitive when combined with noise. What about gradient index materials? What is the default for a chamfer, for example 0. If neither of these is used, the component must be manufactured from the indicated material without substitution.

Last modified: May 21, 2020